| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) is vulnerable to Broken Access Control in initial configuration wizard.cgi endpoint. Malicious attacker can change admin panel password without authorization. The vulnerability can also be exploited after the initial configuration has been set.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future. |
| The ASPECT system allows users to bypass authentication.
This issue affects all versions of ASPECT |
| Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14. |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to manipulate the device via a specific functionality. |
| GALAYOU G2 cameras stream video output via RTSP streams. By default these streams are protected by randomly generated credentials. However these credentials are not required to access the stream. Changing these values does not change camera's behavior.
The vendor did not respond in any way. Only version 11.100001.01.28 was tested, other versions might also be vulnerable. |
| The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access. |
| Tinycontrol LAN Controller v3 (LK3) firmware versions up to 1.58a (hardware v3.8) contain a missing authentication vulnerability in the stm.cgi endpoint. A remote, unauthenticated attacker can send crafted requests to forcibly reboot the device or restore factory settings, leading to a denial of service and configuration loss. |
| Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication. |
| A vulnerability in XAMPP, developed by Apache Friends, version 1.7.3's default WebDAV configuration allows remote authenticated attackers to upload and execute arbitrary PHP code. The WebDAV service, accessible via /webdav/, accepts HTTP PUT requests using default credentials. This permits attackers to upload a malicious PHP payload and trigger its execution via a subsequent GET request, resulting in remote code execution on the server. |
| DBPower C300 HD Camera contains a configuration disclosure vulnerability that allows unauthenticated attackers to retrieve sensitive credentials through an unprotected configuration backup endpoint. Attackers can download the configuration file and extract hardcoded username and password by accessing the /tmpfs/config_backup.bin resource. |
| The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device. |
| Locally installed application can bypass the permission check and perform system operations that require permission. |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. |
| PLANEX CS-QP50F-ING2 smart cameras expose a configuration backup interface over HTTP that does not require authentication. A remote, unauthenticated attacker can directly retrieve a compressed configuration backup file from the device. The backup contains sensitive configuration information, including credentials, allowing an attacker to obtain administrative access to the camera and compromise the confidentiality of the monitored environment. |
| Denver SHO-110 IP cameras expose a secondary HTTP service on TCP port 8001 that provides access to a '/snapshot' endpoint without authentication. While the primary web interface on port 80 enforces authentication, the backdoor service allows any remote attacker to retrieve image snapshots by directly requesting the 'snapshot' endpoint. An attacker can repeatedly collect snapshots and reconstruct the camera stream, compromising the confidentiality of the monitored environment. |
| Unified Remote 3.9.0.2463 contains a remote code execution vulnerability that allows attackers to send crafted network packets to execute arbitrary commands. Attackers can exploit the service by connecting to port 9512 and sending specially crafted packets to open a command prompt and download and execute malicious payloads. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| A vulnerability has been identified in which Rancher does not automatically clean up a user which has been deleted from the configured authentication provider (AP). This characteristic also applies to disabled or revoked users, Rancher will not reflect these modifications which may leave the user’s tokens still usable. |