| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| OpenMQ exposes a TCP-based management service (imqbrokerd) that by default requires
authentication. However, the product ships with a default administrative account (admin/
admin) and does not enforce a mandatory password change on first use. After the first
successful login, the server continues to accept the default password indefinitely without
warning or enforcement.
In real-world deployments, this service is often left enabled without changing the default
credentials. As a result, a remote attacker with access to the service port could authenticate
as an administrator and gain full control of the protocol’s administrative features. |
| Istio is an open platform to connect, manage, and secure microservices. Prior to 1.29.1, 1.28.5, and 1.27.8, a user of Istio is impacted if the JWKS resolver becomes unavailable or the fetch fails, exposing hardcoded defaults regardless of use of the RequestAuthentication resource. This vulnerability is fixed in 1.29.1, 1.28.5, and 1.27.8. |
| Legacy Vivotek Device firmware uses default credetials for the root and user login accounts. |
| By default, the password for the Access Manager's web interface, is set to 'admin'. In the tested version changing the password was not enforced. |
| Default credentials vulnerability exists in SuprOS
product. If exploited, this could allow an authenticated
local attacker to use an admin account created during
product deployment. |
| A vulnerability was identified in TRENDnet TI-G160i, TI-PG102i and TPL-430AP up to 20250724. This affects an unknown part of the component SSH Service. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The vendor explains: "For product TI-PG102i and TI-G160i, by default, the product's remote management options are all disabled. The root account is for troubleshooting purpose and the password is encrypted. However, we will remove the root account from the next firmware release. For product TPL-430AP, the initial setup process requires user to set the password for the management GUI. Once that was done, the default password will be invalid." |
| A credential management flaw in Palo Alto Networks Cortex XDR® Broker VM causes different Broker VM images to share identical default credentials for internal services. Users knowing these default credentials could access internal services on other Broker VM installations.
The attacker must have network access to the Broker VM to exploit this issue. |
| MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials. |
| IO-1020 Micro ELD uses a default WIFI password that could allow an adjacent attacker to connect to the device.
|
| IO-1020 Micro ELD web server uses a default password for authentication.
|
| If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface
protected by authentication. If the default credentials are not changed,
an attacker can use public knowledge to access the device as an
administrator. |
| NetBird VPN when installed using vendor's provided script failed to remove or change default password of an admin account created by ZITADEL.
This issue affects instances installed using vendor's provided script. This issue may affect instances created with Docker if the default password was not changed nor the user was removed.
This issue has been fixed in version 0.57.0 |
| Authentication credentials leakage vulnerability in Hitachi Ops Center Analyzer viewpoint.This issue affects Hitachi Ops Center Analyzer viewpoint: from 10.0.0-00 before 11.0.4-00. |
| A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords". |
| CWE-1392: Use of Default Credentials |
| Control-M/Agents use a kdb or PKCS#12 keystore by default, and the default keystore password is well known and documented.
An attacker with read access to the keystore could access sensitive data using this password. |
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. |
| ANCHOR from Global Wisdom Software is an integrated product running on a Windows virtual machine. The underlying Windows OS of the product contains high-privilege service accounts. If these accounts use default passwords, attackers could remotely log in to the virtual machine using the default credentials. |
| A vulnerability in the Eclipse Vert.x toolkit causes a memory leak in TCP servers configured with TLS and SNI support. When processing an unknown SNI server name assigned the default certificate instead of a mapped certificate, the SSL context is erroneously cached in the server name map, leading to memory exhaustion. This flaw allows attackers to send TLS client hello messages with fake server names, triggering a JVM out-of-memory error. |
| Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory.
For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created.
Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared.
Newer firmware versions might be vulnerable as well. |