| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges. |
| luci-app-lucky v2.8.3 was discovered to contain hardcoded credentials. |
| The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices. |
| Aptos Wisal payroll accounting before 7.1.6 uses hardcoded credentials in the Windows client to fetch the complete list of usernames and passwords from the database server, using an unencrypted connection. This allows attackers in a machine-in-the-middle position read and write access to personally identifiable information (PII) and especially payroll data and the ability to impersonate legitimate users with respect to the audit log. |
| There are several hidden accounts. Some of them are intended for maintenance engineers, and with the knowledge of their passwords (e.g., by examining the coredump), these accounts can be used to re-configure the device. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| A hardcoded privileged ID within Lumisxp v15.0.x to v16.1.x allows attackers to bypass authentication and access internal pages and other sensitive information. |
| 'OfferBox' App for Android versions 2.0.0 to 2.3.17 and 'OfferBox' App for iOS versions 2.1.7 to 2.6.14 use a hard-coded secret key for JWT. Secret key for JWT may be retrieved if the application binary is reverse-engineered. |
| The application uses several hard-coded credentials to encrypt config files during backup, to decrypt the new firmware during an update and some passwords allow a direct connection to the database server of the affected device. |
| Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
|
| api is a module for FreePBX@, which is an open source GUI that controls and manages Asterisk© (PBX). In versions lower than 15.0.13, 16.0.2 through 16.0.14, 17.0.1 and 17.0.2, there is an identical OAuth private key used across multiple systems that installed the same FreePBX RPM or DEB package. An attacker with access to the shared OAuth private key could forge JWT tokens, bypass authentication, and potentially gain full access to both REST and GraphQL APIs. Systems with the "api" module enabled, configured and previously activated by an administrator for remote inbound connections may be affected. This issue is fixed in versions 15.0.13, 16.0.15 and 17.0.3. |
| Array Networks vAPV (version 8.3.2.17) and vxAG (version 9.2.0.34) appliances are affected by a privilege escalation vulnerability caused by a combination of hardcoded SSH credentials (or SSH private key) and insecure permissions on a startup script. The devices ship with a default SSH login or a hardcoded DSA private key, allowing an attacker to authenticate remotely with limited privileges.
Once authenticated, an attacker can overwrite the world-writable /ca/bin/monitor.sh script with arbitrary commands. Since this script is executed with elevated privileges through the backend binary, enabling the debug monitor via backend -c "debug monitor on" triggers execution of the attacker's payload as root. This allows full system compromise. |
| Precor touchscreen console P62, P80, and P82 contains a default SSH public key in the authorized_keys file. A remote attacker could use this key to gain root privileges. |
| Precor touchscreen console P62, P80, and P82 could allow a remote attacker to obtain sensitive information because the root password is stored in /etc/passwd. An attacker could exploit this to extract files and obtain sensitive information. |
| Precor touchscreen console P62, P80, and P82 could allow a remote attacker (within the local network) to bypass security restrictions, and access the service menu, because there is a hard-coded service code. |
| Precor touchscreen console P82 contains a private SSH key that corresponds to a default public key. A remote attacker could exploit this to gain root privileges. |
| The program libraries (DLL) and binaries used by exos 9300 contain multiple hard-coded secrets. One notable example is the function "EncryptAndDecrypt" in the library Kaba.EXOS.common.dll. This algorithm uses a simple XOR encryption technique combined with a cryptographic key (cryptoKey) to transform each character of the input string. However, it's important to note that this implementation does not provide strong encryption and should not be considered secure for sensitive data. It's more of a custom encryption approach rather than a common algorithm used in cryptographic applications. The key itself is static and based on the founder's name of the company. The functionality is for example used to encrypt the user PINs before storing them in the MSSQL database. |
| An RPC service, which is part of exos 9300, is reachable on port 4000, run by the process FSMobilePhoneInterface.exe. This service is used for interprocess communication between services and the Kaba exos 9300 GUI, containing status information about the Access Managers. Interacting with the service does not require any authentication. Therefore, it is possible to send arbitrary status information about door contacts etc. without prior authentication. |
| Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020. |
| MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs. |
| FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system. |