Export limit exceeded: 371163 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (371163 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2021-38453 | 1 Auvesy | 1 Versiondog | 2024-11-21 | 9.1 Critical |
| Some API functions allow interaction with the registry, which includes reading values as well as data modification. | ||||
| CVE-2021-38452 | 1 Moxa | 1 Mxview | 2024-11-21 | 7.5 High |
| A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries. | ||||
| CVE-2021-38451 | 1 Auvesy | 1 Versiondog | 2024-11-21 | 4.8 Medium |
| The affected product’s proprietary protocol CSC allows for calling numerous function codes. In order to call those function codes, the user must supply parameters. There is no sanitation on the value of the offset, which allows the client to specify any offset and read out-of-bounds data. | ||||
| CVE-2021-38450 | 1 Trane | 5 Tracer Concierge, Tracer Sc, Tracer Sc\+ and 2 more | 2024-11-21 | 9.9 Critical |
| The affected controllers do not properly sanitize the input containing code syntax. As a result, an attacker could craft code to alter the intended controller flow of the software. | ||||
| CVE-2021-38449 | 1 Auvesy | 1 Versiondog | 2024-11-21 | 9.8 Critical |
| Some API functions permit by-design writing or copying data into a given buffer. Since the client controls these parameters, an attacker could rewrite the memory in any location of the affected product. | ||||
| CVE-2021-38448 | 1 Trane | 6 Ascend Air-cooled Chiller Acr, Intellipak 1, Intellipak 2 and 3 more | 2024-11-21 | 7.5 High |
| The affected controllers do not properly sanitize the input containing code syntax. As a result, an attacker could craft code to alter the intended controller flow of the software. | ||||
| CVE-2021-38442 | 1 Fatek | 1 Winproladder | 2024-11-21 | 7.8 High |
| FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in a heap-corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. | ||||
| CVE-2021-38440 | 1 Fatek | 1 Winproladder | 2024-11-21 | 3.3 Low |
| FATEK Automation WinProladder versions 3.30 and prior is vulnerable to an out-of-bounds read, which may allow an attacker to read unauthorized information. | ||||
| CVE-2021-38438 | 1 Fatek | 1 Winproladder | 2024-11-21 | 7.8 High |
| A use after free vulnerability in FATEK Automation WinProladder versions 3.30 and prior may be exploited when a valid user opens a malformed project file, which may allow arbitrary code execution. | ||||
| CVE-2021-38436 | 1 Fatek | 1 Winproladder | 2024-11-21 | 7.8 High |
| FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in a memory-corruption condition. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process. | ||||
| CVE-2021-38434 | 1 Fatek | 1 Winproladder | 2024-11-21 | 7.8 High |
| FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in an unexpected sign extension. An attacker could leverage this vulnerability to execute arbitrary code. | ||||
| CVE-2021-38432 | 1 Fatek | 2 Communication Server, Communication Server Firmware | 2024-11-21 | 9.8 Critical |
| FATEK Automation Communication Server Versions 1.13 and prior lacks proper validation of user-supplied data, which could result in a stack-based buffer overflow condition and allow an attacker to remotely execute code. | ||||
| CVE-2021-38431 | 1 Advantech | 1 Webaccess Scada | 2024-11-21 | 4.3 Medium |
| An authenticated user using Advantech WebAccess SCADA in versions 9.0.3 and prior can use API functions to disclose project names and paths from other users. | ||||
| CVE-2021-38430 | 1 Fatek | 1 Winproladder | 2024-11-21 | 7.8 High |
| FATEK Automation WinProladder versions 3.30 and prior proper validation of user-supplied data when parsing project files, which could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute arbitrary code. | ||||
| CVE-2021-38428 | 1 Deltaww | 1 Dialink | 2024-11-21 | 5.5 Medium |
| Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code. | ||||
| CVE-2021-38426 | 1 Fatek | 1 Winproladder | 2024-11-21 | 7.8 High |
| FATEK Automation WinProladder versions 3.30 and prior lacks proper validation of user-supplied data when parsing project files, which could result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code. | ||||
| CVE-2021-38424 | 1 Deltaww | 1 Dialink | 2024-11-21 | 5.9 Medium |
| The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application. | ||||
| CVE-2021-38422 | 1 Deltaww | 1 Dialink | 2024-11-21 | 7.8 High |
| Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges. | ||||
| CVE-2021-38421 | 1 Fujielectric | 2 V-server, V-simulator | 2024-11-21 | 7.8 High |
| Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds read, which may allow an attacker to read sensitive information from other memory locations or cause a crash. | ||||
| CVE-2021-38420 | 1 Deltaww | 1 Dialink | 2024-11-21 | 7.8 High |
| Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files. | ||||