Search Results (3725 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2011-10010 2026-04-15 N/A
QuickShare File Server 1.2.1 contains a path traversal vulnerability in its FTP service due to improper sanitation of user-supplied file paths. Authenticated users can exploit this flaw by submitting crafted sequences to access or write files outside the intended virtual directory. When the "Writable" option is enabled (default during account creation), this allows attackers to upload arbitrary files to privileged locations such as system32, enabling remote code execution via MOF injection or executable placement.
CVE-2017-20214 1 Flir 1 Thermal Camera 2026-04-15 7.5 High
FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43698 1 Kieback\&peter 10 Ddc4002 Firmware, Ddc4002e Firmware, Ddc4020e Firmware and 7 more 2026-04-15 9.8 Critical
Kieback & Peter's DDC4000 series uses weak credentials, which may allow an unauthenticated attacker to get full admin rights on the system.
CVE-2025-41426 2026-04-15 9.8 Critical
Affected Vertiv products contain a stack based buffer overflow vulnerability. An attacker could exploit this vulnerability to gain code execution on the device.
CVE-2025-46412 2026-04-15 9.8 Critical
Affected Vertiv products do not properly protect webserver functions that could allow an attacker to bypass authentication.
CVE-2025-40805 1 Siemens 24 Industrial Edge Cloud Device (iecd), Industrial Edge Device Kit, Industrial Edge Own Device (ieod) and 21 more 2026-04-15 10 Critical
Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.
CVE-2025-41006 1 Imaster 1 Mems Events Crm 2026-04-15 N/A
Imaster's MEMS Events CRM contains an SQL injection vulnerability in ‘phone’ parameter in ‘/memsdemo/login.php’.
CVE-2025-32428 2026-04-15 N/A
Jupyter Remote Desktop Proxy allows you to run a Linux Desktop on a JupyterHub. jupyter-remote-desktop-proxy was meant to rely on UNIX sockets readable only by the current user since version 3.0.0, but when used with TigerVNC, the VNC server started by jupyter-remote-desktop-proxy were still accessible via the network. This vulnerability does not affect users having TurboVNC as the vncserver executable. This issue is fixed in 3.0.1.
CVE-2025-14346 2026-04-15 9.8 Critical
WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction.
CVE-2025-22372 2026-04-15 N/A
Insufficiently Protected Credentials vulnerability in SicommNet BASEC on SaaS allows Password Recovery. Passwords are either stored in plain text using reversible encryption, allowing an attacker with sufficient privileges to extract plain text passwords easily. This issue affects BASEC: from 14 Dec 2021.
CVE-2011-10015 2026-04-15 N/A
Cytel Studio version 9.0 and earlier is vulnerable to a stack-based buffer overflow triggered by parsing a malformed .CY3 file. The vulnerability occurs when the application copies user-controlled strings into a fixed-size stack buffer (256 bytes) without proper bounds checking. Exploitation allows arbitrary code execution when the crafted file is opened.
CVE-2011-10016 2026-04-15 N/A
Real Networks Netzip Classic version 7.5.1.86 is vulnerable to a stack-based buffer overflow when parsing a specially crafted ZIP archive. The vulnerability is triggered when the application attempts to process a file name within the archive that exceeds the expected buffer size. Exploitation allows arbitrary code execution under the context of the victim user when the ZIP file is opened.
CVE-2011-10017 1 Snort 1 Snort 2026-04-15 N/A
Snort Report versions < 1.3.2 contains a remote command execution vulnerability in the nmap.php and nbtscan.php scripts. These scripts fail to properly sanitize user input passed via the target GET parameter, allowing attackers to inject arbitrary shell commands. Exploitation requires no authentication and can result in full compromise of the underlying system.
CVE-2011-10032 2 Microsoft, Sunwayland 2 Windows, Forcecontrol 2026-04-15 N/A
Sunway ForceControl version 6.1 SP3 and earlier contains a stack-based buffer overflow vulnerability in the SNMP NetDBServer service, which listens on TCP port 2001. The flaw is triggered when the service receives a specially crafted packet using opcode 0x57 with an overly long payload. Due to improper bounds checking during packet parsing, attacker-controlled data overwrites the Structured Exception Handler (SEH), allowing arbitrary code execution in the context of the service. This vulnerability can be exploited remotely without authentication and may lead to full system compromise on affected Windows hosts.
CVE-2012-10025 3 Accesspressthemes, Advanced Custom Fields, Wordpress 3 Frontend Post Wordpress Plugin, Advanced Custom Fields Wordpress Plugin, Wordpress 2026-04-15 N/A
The WordPress plugin Advanced Custom Fields (ACF) version 3.5.1 and below contains a remote file inclusion (RFI) vulnerability in core/actions/export.php. When the PHP configuration directive allow_url_include is enabled (default: Off), an unauthenticated attacker can exploit the acf_abspath POST parameter to include and execute arbitrary remote PHP code. This leads to remote code execution under the web server’s context, allowing full compromise of the host.