| MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service (master-station daemon crash) via a malformed DNP3 TCP packet from the IP address of an outstation. |
| Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |
| Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |
| The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (memory consumption or memory corruption, instance shutdown, and data-collection outage) via crafted C37.118 configuration packets. |
| The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (instance shutdown and data-collection outage) via crafted C37.118 configuration packets that trigger an invalid read operation. |
| The universal protocol implementation in Sixnet UDR before 2.0 and RTU firmware before 4.8 allows remote attackers to execute arbitrary code; read, modify, or create files; or obtain file metadata via function opcodes. |
| ProSoft RadioLinx ControlScape before 6.00.040 uses a deficient PRNG algorithm and seeding strategy for passphrases, which makes it easier for remote attackers to obtain access via a brute-force attack. |
| The DNP Master Driver in Software Toolbox TOP Server before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line. |
| Use-after-free vulnerability in the O3D plug-in in Google Chrome OS before 26.0.1410.57 allows remote attackers to cause a denial of service or possibly have unspecified other impact via vectors related to improper management of ownership relationships involving Elements and DrawElements. |
| The DNP3 component in Cooper Power Systems SMP 4, 4/DP, and 16 gateways allows remote attackers to cause a denial of service (reboot or link outage) via a crafted DNP3 TCP packet. |
| Cooper Power Systems Cybectec DNP3 Master OPC Server allows remote attackers to cause a denial of service (unhandled exception and process crash) via unspecified vectors. |
| The DNP3 component in Cooper Power Systems SMP 4, 4/DP, and 16 gateways allows physically proximate attackers to cause a denial of service (reboot or link outage) via crafted input over a serial line. |
| An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arbitrary programs via a crafted HTML document in conjunction with a Login Client button click. |
| The DNP Master Driver in Alstom e-terracontrol 3.5, 3.6, and 3.7 allows physically proximate attackers to cause a denial of service (infinite loop and DNP3 service disruption) via crafted input over a serial line. |
| The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to reprogram the firmware via a replay attack using UDP ports 17336 and 17388. |
| NovaTech Orion Substation Automation Platform OrionLX DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier and Orion5/Orion5r DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier allow remote attackers to cause a denial of service (driver crash and process restart) via a crafted DNP3 TCP packet. |
| NovaTech Orion Substation Automation Platform OrionLX DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier and Orion5/Orion5r DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier allow physically proximate attackers to cause a denial of service (driver crash and process restart) via crafted input over a serial line. |
| The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |