| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The DNP3 driver in IOServer drivers 1.0.19.0 allows remote attackers to cause a denial of service (infinite loop) or obtain unspecified control via crafted data to TCP port 20000. |
| Triangle Research International (aka Tri) Nano-10 PLC devices with firmware before r81 use an incorrect algorithm for bounds checking of data in Modbus/TCP packets, which allows remote attackers to cause a denial of service (networking outage) via a crafted packet to TCP port 502. |
| Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624. |
| Alstom Grid MiCOM S1 Agile before 1.0.3 and Alstom Grid MiCOM S1 Studio use weak permissions for the MiCOM S1 %PROGRAMFILES% directory, which allows local users to gain privileges via a Trojan horse executable file. |
| The DNP3 Slave service in SUBNET Solutions SubSTATION Server 2.7.0033 and 2.8.0106 allows remote attackers to cause a denial of service (unhandled exception and process crash) via unspecified vectors. |
| The Kepware DNP Master Driver for the KEPServerEX Communications Platform before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line. |
| The master-station DNP3 driver before driver19.exe, and Beta2041.exe, in IOServer allows remote attackers to cause a denial of service (infinite loop) via crafted DNP3 packets to TCP port 20000. |
| MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service (master-station daemon crash) via a malformed DNP3 TCP packet from the IP address of an outstation. |
| Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |
| Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. |
| Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |
| The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (memory consumption or memory corruption, instance shutdown, and data-collection outage) via crafted C37.118 configuration packets. |
| The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (instance shutdown and data-collection outage) via crafted C37.118 configuration packets that trigger an invalid read operation. |
| The universal protocol implementation in Sixnet UDR before 2.0 and RTU firmware before 4.8 allows remote attackers to execute arbitrary code; read, modify, or create files; or obtain file metadata via function opcodes. |
| ProSoft RadioLinx ControlScape before 6.00.040 uses a deficient PRNG algorithm and seeding strategy for passphrases, which makes it easier for remote attackers to obtain access via a brute-force attack. |
| The DNP Master Driver in Software Toolbox TOP Server before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line. |
| Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000. |
| Use-after-free vulnerability in the O3D plug-in in Google Chrome OS before 26.0.1410.57 allows remote attackers to cause a denial of service or possibly have unspecified other impact via vectors related to improper management of ownership relationships involving Elements and DrawElements. |