| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A Resource Consumption issue was discovered in Trihedral VTScada Versions prior to 11.2.26. The client does not properly validate the input or limit the amount of resources that are utilized by an attacker, which can be used to consume more resources than are available. |
| A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device. |
| A Heap-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow when a maliciously crafted project file is run by the system. |
| A Server-Side Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web server receives a request, but does not sufficiently verify that the request is being sent to the expected destination. |
| A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path. |
| A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers for scripting syntax" issue has been identified, which may allow remote code execution. |
| A Cross-Site Scripting issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. This may allow remote code execution. |
| A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code. |
| A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database. |
| An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot. |
| An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input. |
| Xen through 4.8.x allows local x86 PV guest OS kernel administrators to cause a denial of service (host hang or crash) by modifying the instruction stream asynchronously while performing certain kernel operations. |
| Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account. |
| A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover. |
| In SWFTools 2013-04-09-1007 on Windows, png2swf allows remote attackers to cause a denial of service or possibly have unspecified other impact via a crafted file, related to a "Read Access Violation starting at image00000000_00400000+0x000000000001b5fe." |
| An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The following versions are affected: Versions 4.1 and prior versions released before January 20, 2017. An Improper Access Control vulnerability has been identified, which may allow an authenticated user to modify application files to escalate privileges. |
| In SWFTools 2013-04-09-1007 on Windows, png2swf allows remote attackers to cause a denial of service or possibly have unspecified other impact via a crafted file, related to a "Read Access Violation starting at image00000000_00400000+0x000000000001b596." |
| In Wireshark 2.2.4 and earlier, a crafted or malformed STANAG 4607 capture file will cause an infinite loop and memory exhaustion. If the packet size field in a packet header is null, the offset to read from will not advance, causing continuous attempts to read the same zero length packet. This will quickly exhaust all system memory. |
| An issue was discovered in icoutils 0.31.1. An out-of-bounds read leading to a buffer overflow was observed in the "simple_vec" function in the "extract.c" source file. This affects icotool. |
| An issue was discovered in icoutils 0.31.1. A buffer overflow was observed in the "extract_icons" function in the "extract.c" source file. This issue can be triggered by processing a corrupted ico file and will result in an icotool crash. |